D4C-3202 OMRON Travel Switch NEW
Data Sheet | D4C-3202 Travel Switch NEW |
OMRON Travel Switch D4C-3202
Product Description:
Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and diaphragm; switch section sealed via nitrile rubber cap; cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models. Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy confirmation of operation. (Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking. (Applicable only to standard models.)
Specifications:
Degree of protection | IP67 | |
Durability *1 | Mechanical *3 | 10,000,000 operations min. |
Electrical *2 | 200,000 operations min. (5 A at 125 VAC, resistive load) | |
Operating speed | 0.1 mm/s to 0.5 m/s (in case of plunger) | |
1 mm/s to 1 m/s (in case of roller lever) | ||
Operating | Mechanical | 120 operations/min |
frequency | Electrical | 30 operations/min |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 M Ω min. (at 500 VDC) | |
Contact resistance (initial) | 250 m Ω max. (initial value with 2-m VCTF cable) | |
300 m Ω max. (initial value with 3-m VCTF cable) | ||
400 m Ω max. (initial value with 5-m VCTF cable) | ||
Dielectric | Between terminals of the same polarity | 1,000 VAC, 50/60 Hz for 1 min |
strength | Between current-carrying metal part | 1,500 VAC, 50/60 Hz for 1 min |
| and ground | Uimp: 2.5 kV (EN60947-5-1) |
| Between each terminal and non-current- | 1,500 VAC, 50/60 Hz for 1 min |
| carrying metal part, | Uimp: 2.5 kV (EN60947-5-1) |
Rated insulation voltage (Ui) | 300 V (EN60947-5-1) *5 | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Short-circuit protective device (SCPD) | 10 A fuse type gI or gG (IEC60269) | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (I the) | 5 A, 4 A, 0.5 A (EN60947-5-1) | |
Protection against electric shock | Class I (with grounding wire) *6 | |
Vibration | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *4 |
resistance | ||
Shock | Destruction | 1,000 m/s2 min. |
resistance | Malfunction | 500 m/s2 min. *4 |
Ambient operating temperature | -10 ° C to +70 ° C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight (D4C-1202) | With 3-m VCTF cable: 360 g | |
With 5-m VCTF cable: 540 g |
Note:The above figures are initial values.
*1.The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
*2.Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)
*3.Outdoor specifications: 500,000 operations min.
*4.Excluding Plastic Rods.
*5.Pre-wired models: 250 V
*6.Pre-wired models: class III
المنتج لا يمكن استخدامه في فترة الضمان بسبب مشاكل جودة المنتج
المنتج تالف أثناء الشحن
لم يتم تسليم المنتج في الوقت المحدد بسبب سبب من أسبابنا
يرسل المشترون بريدًا إلكترونيًا إلى خدمة العملاء لدينا لوصف المشكلة وتقديم الأدلة (صور واضحة أو لقطات شاشة أو فيديو).
سنتحقق من المشكلة في يوم عمل واحد. للحالات المؤهلة ، سنقوم بتقديم استبدال مجاني أو استرداد كامل في غضون يومي عمل واحد إلى يومين.
إذا كانت هناك حاجة للإرجاع ، فسيتم دفع رسوم شحن الإرجاع من قبلنا.
D4C-3202 Travel Switch NEW
Gross Weight | 0.25 |
---|