Skype.me! Live chat FAQ

Indkøbskurv(0)

E2E-X8MD1S-Z Proximity Switch NEW

48,98 $

E2E-X8MD1S-Z OMRON Proximity Switch NEW

Datablad E2E-X8MD1S-Z Proximity Switch NEW

Product Description:

Standard Sensors for detecting ferrous metals.

Wide array of variations. Ideal for a variety of applications.

Models with different frequencies are also available to prevent mutual interference.

Superior environment resistance with standard cable made of oilresistant PVC and sensing surface made of material that resists cutting oil.

Specifications:

Size

M8

M12

M18

M30

Shielded

Shielded

Unshielded

Shielded

Unshielded

Shielded

Unshielded

Shielded

Unshielded

Model

E2E-

E2E-

E2E-

E2E-

E2E-

E2E-

E2E-

E2E-

X2D[]

X4MD[]

X3D[]

X8MD[]

X7D[]

X14MD[]

X10D[]

X20MD[]

Sensing distance

2 mm ±10%

4 mm ±10%

3 mm ±10%

8 mm ±10%

7 mm ±10%

14 mm ±10%

10 mm ±10%

20 mm ±10%

Set distance *1

0 to 1.6 mm

0 to 3.2 mm

0 to 2.4 mm

0 to 6.4 mm

0 to 5.6 mm

0 to 11.2 mm

0 to 8 mm

0 to 16 mm

Differential travel

15% max. of sensing distance

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Data Sheet.)

Standard sensing

Iron, 8 ×

Iron, 20 ×

Iron, 12 ×

Iron, 30 ×

Iron, 18 ×

Iron, 30 × 30 × 1 mm

Iron, 54 ×

object

8 × 1 mm

20 × 1 mm

12 × 1 mm

30 × 1 mm

18 × 1 mm

54 × 1 mm

Response frequency

1.5 kHz

1 kHz

0.8 kHz

0.5 kHz

0.4 kHz

0.1 kHz

*2

Power supply voltage

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

(operating voltage

range)

Leakage current

0.8 mA max.

Control

Load

3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models

output

current

 

Residual

3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)

 

voltage

 

*3

Indicators

D1 Models: Operation indicator (red) and setting indicator (green)

D2 Models: Operation indicator (red)

Operation mode

D1 Models: NO

(with sensing object

D2 Models: NC

approaching)

Refer to Data Sheet.

Diagnostic output

0.3 to 1 s

delay

Protection circuits

Surge suppressor, Load short-circuit protection (for control and diagnostic output)

Ambient

Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)

temperature range

Ambient

Operating/storage: 35% to 95% (with no condensation)

humidity range

Temperature

±15% max. of sensing

±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

influence

distance at 23°C in the

 

temperature range of -25

 

to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1000 VAC, 50/60 Hz for 1 minute between current carry parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 500 m/s2

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

10 times each in X, Y, and

Z directions

Degree of protection

Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant

Connector Models: IEC 60529 IP67

Connection method

Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)

Weight

Pre-wired

Approx. 60 g

Approx. 70 g

Approx. 130 g

Approx. 175 g

(packed

Models

state)

Pre-wired

---

Approx. 40 g

Approx. 70 g

Approx. 110 g

 

Connector

 

Models

 

Connector

Approx. 15 g

Approx. 25 g

Approx. 40 g

Approx. 90 g

 

Models

Materi-

Case

Stainless steel (SUS303)

Nickel-plated brass

als

Sensing

PBT

 

surface

 

Clamping

Nickel-plated brass

 

nuts

 

Toothed

Zinc-plated iron

 

washer

Accessories

Instruction manual

*1.Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).

*2.The response frequency is an average value.

Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.

*3.The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to Data Sheet for details.)

 

loading...
I følgende tilfælde vil vi foretage en gratis ombytning eller fuld refusion:

Produktet kan ikke bruges i garantiperioden på grund af produktkvalitetsproblemer

Produktet er beskadiget under transport

Produktet er ikke leveret til tiden på grund af vores skyld


Proces for gratis ombytning eller fuld refusion:

Køberne sender en e-mail til vores kundeservice for at beskrive problemet og give beviser (klare fotos, skærmbilleder eller video)

Vi vil undersøge problemet inden for 1 arbejdsdag. For kvalificerede tilfælde vil vi give en gratis ombytning eller fuld refusion inden for 1-2 arbejdsdage

Hvis der kræves en retur, vil returforsendelsesgebyret blive betalt af os

E2E-X8MD1S-Z Proximity Switch NEW

Gross Weight 0.1
credit card