Skype.me! Live Chat FAQ

Warenkorb(0)

D4C-3220 Travel Switch NEW

54,00 $

D4C-3220 OMRON Travel Switch NEW

Datenblatt D4C-3220 Travel Switch NEW

OMRON Travel Switch D4C-3220   

Product Description:

Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)

Sealing characteristics that meet IEC IP67 degree of protection.

Triple-sealed construction:

Plunger section sealed via nitrile rubber packing seal and diaphragm; switch section sealed via nitrile rubber cap; cable entrance sealed via encapsulating material.

Cable lengths of 3 and 5 m available on standard models. Models also available with UL and CSA-certified cables.

Multiple mounting possible with Switches with Plungers.

Models with red LED indicators added to series for easy confirmation of operation. (Set by default to light for non-operation.)

VCTF oil-resistant cables with CE marking. (Applicable only to standard models.)  

Specifications:

Degree of protection

IP67

Durability *1

Mechanical *3

10,000,000 operations min.

Electrical *2

200,000 operations min. (5 A at 125 VAC, resistive load)

Operating speed

0.1 mm/s to 0.5 m/s (in case of plunger)

1 mm/s to 1 m/s (in case of roller lever)

Operating

Mechanical

120 operations/min

frequency

Electrical

30 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 M Ω min. (at 500 VDC)

Contact resistance (initial)

250 m Ω max. (initial value with 2-m VCTF cable)

300 m Ω max. (initial value with 3-m VCTF cable)

400 m Ω max. (initial value with 5-m VCTF cable)

Dielectric

Between terminals of the same polarity

1,000 VAC, 50/60 Hz for 1 min

strength

Between current-carrying metal part

1,500 VAC, 50/60 Hz for 1 min

 

and ground

Uimp: 2.5 kV (EN60947-5-1)

 

Between each terminal and non-current-

1,500 VAC, 50/60 Hz for 1 min

 

carrying metal part,

Uimp: 2.5 kV (EN60947-5-1)

Rated insulation voltage (Ui)

300 V (EN60947-5-1) *5

Pollution degree (operating environment)

3 (EN60947-5-1)

Short-circuit protective device (SCPD)

10 A fuse type gI or gG (IEC60269)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional enclosed thermal current (I the)

5 A, 4 A, 0.5 A (EN60947-5-1)

Protection against electric shock

Class I (with grounding wire) *6

Vibration

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *4

resistance

Shock

Destruction

1,000 m/s2 min.

resistance

Malfunction

500 m/s2 min. *4

Ambient operating temperature

-10 ° C to +70 ° C (with no icing)

Ambient operating humidity

35% to 95%RH

Weight (D4C-1202)

With 3-m VCTF cable: 360 g

With 5-m VCTF cable: 540 g

 

Note:The above figures are initial values.

*1.The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.

*2.Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)

*3.Outdoor specifications: 500,000 operations min.

*4.Excluding Plastic Rods.

*5.Pre-wired models: 250 V

*6.Pre-wired models: class III

 

loading...
Für die folgenden Umstände werden wir kostenlos Ersatz oder volle Rückerstattung arrangieren

Innerhalb von der Garantie aufgrund von Problemen mit der Produktqualität führt es dazu, dass das Produkt nicht verwendet werden kann

Die Ware wird während des Transports beschädigt

Das Produkt wurde aufgrund unseres Verschuldens nicht rechtzeitig geliefert.


Ablauf für kostenlosen Ersatz oder vollständige Rückerstattung

Der Käufer sendet unserem Kundenservice eine E-Mail, um das Problem zu beschreiben und unterstützende Dokumente bereitzustellen (klares Foto, Screenshot oder Video)

Wir überprüfen das Problem innerhalb von 1-3 Werktagen. Wenn der Antrag gerechtet ist, wird innerhalb von 1-2 Tagen kostenloser Ersatz oder Rückerstattung arrangiert

Wenn eine Rücksendung erforderlich ist, wird die Rücksendegebühr von uns bezahlt

D4C-3220 Travel Switch NEW

Gross Weight 0.25
credit card