DC 3-Wire Model , Flat Type , Unshielded , Sensing Distance 10mm , Operation Mode NO.
Specifications:
Type | Unshielded |
Sensing method | Capacitive type |
Sensing distance | 10 mm -10% to +10% |
Setting distance | 0 to 7.5 mm |
Differential distance | 15% Max. of sensing distance |
Sensing object | Conductor and dielectrics |
Standard sensing object | With grounded metal 50*50*1mm |
Response frequency | DC: 100 Hz (average) |
Power supply voltage | 12 to 24 VDC (ripple(p-p) :10% Max.) |
Operating voltage range | 10 to 30 VDC |
Current consumption | 10 mA Max. (at 24VDC) |
Control output (Output type) | NPN open collector output |
Control output (Switching capacity) | 0 to 100 mA (at 30VDC) |
Control output (Residual voltage) | (DC) 1.5 V Max. (under load current with cable length of 2m) |
Indicator | Detection indicator(red) |
Operation mode | NO |
Protective circuit | Surge suppressor |
Power supply reverse polarity protection | |
Standard or Different frequency | Standard |
Ambient temperature | Operating: -10 to 55 CEL |
Storage: -10 to 55 CEL | |
(with no icing or condensation) | |
Ambient humidity | Operating: 35 to 95 %RH |
Storage: 35 to 95 %RH | |
(with no condensation) | |
Temperature influence | +-15% Max. of sensing distance in temperature range of -10 to +55CEL |
(As the basis for sensing distance of 23CEL) | |
Voltage influence | +-2.5% Max. of sensing distance in rated voltage range +-10%. (As the basis for sensing distance at standard power voltage) |
Insulation resistance | 50 M OHM Min. at 500VDC between charged parts and the case |
Dielectric strength | 500 VAC 50/60 Hz for 1 minute between charged parts and the case |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance | 500m/s2 for 3 times each in X, Y, and Z directions |
Degree of protection | IEC60529: IP66 |
Applicable standard (EC Directive (Low Voltage Directive)) | EN60947-1 |
EN60947-5-2 | |
Applicable standard (EC Directive (EMC Directive)) | EMI: EN60947-5-2 |
Emission Enclosure: CISPR11 Group 1 class A | |
EMS: EN60947-5-2 | |
Immunity ESD: IEC61000-4-2 | |
Immunity RF-interference: IEC61000-4-3 | |
Immunity Conducted Disturbance: IEC61000-4-6 | |
Immunity Burst: IEC61000-4-4 | |
CE marking: Equipped | |
Applicable standard (CCC mark) | Not equipped |
Connection method | Pre-wired models (Cable length: 2 m) |
Weight (Packed state) | approx. 35 g |
Material (case) | Heat-resistant ABS resin |
Material (sensing surface) | Heat-resistant ABS resin |
Accessories | Instruction manual |
Product cannot use in warranty period because of product quality problems
Product is damaged in transit
Product is not delivered in time because of our reason
Buyers send an email to our customer service to describe the problem, and to provide evidence (clear photos, screenshots, or video)
We will check the problem in 1 working days. For eligible cases, we will provide a free replacement or full refund within 1-2 business days
If a return is required, the return shipping fee will be paid by us
E2K-F10MC1 Flat Proximity Sensor NEW
Gross Weight | 0.04 |
---|