E2K-L26MC1 OMRON Proximity Switch NEW
Fiche technique | E2K-L26MC1 Proximity Switch NEW |
OMRON Proximity Switch E2K-L26MC1
Product Description:
Mount to bypass pipes.
Fit a wide range of pipe diameters: 8 to 11 mm or 12 to 26 mm
Built-in Amplifiers to save space.
Specifications:
Model | E2K-L13MC1 | E2K-L26MC1 | ||
Applicable pipes | Materials | Non-metal | ||
Size | Diameter | 8 to 11 mm | 12 to 26 mm | |
Thickness | 1 mm max. | 1.5 mm max. | ||
Detectable object | Liquid * | |||
Repeat accuracy | ±0.2 mm max. | |||
Differential travel | 0.6 to 5 mm | 0.3 to 3 mm | ||
(Reference value, varies with | ||||
pipe size and liquid.) | ||||
Power supply voltage | 12 to 24 VDC (10.8 to 30 VDC), ripple (p-p): 10% max. | |||
(operating voltage range) | ||||
Current consumption | 12 mA max. | |||
Control output | Load current | 100 mA max. | ||
Residual voltage | 1 V max. (Load current: 100 mA, Cable length: 2 m) | |||
Sensing liquid position | Indented mark position (For details, refer to Datasheet) | |||
Indicators | Detection indicator (orange) | |||
Ambient temperature range | Operating: 0 to 55°C (with no icing or condensation), Storage: -10 to 65°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 25% to 85% (with no condensation) | |||
Temperature influence | ±4 mm of detection level at 23°C in the temperature range of 0 to 55°C | |||
(with pure water or 20% saline solution) | ||||
(±6 mm for E2K-L13MC1 with pure water and a pipe diameter of 8 mm) | ||||
Voltage influence | ±0.5 mm of detection level at the rated voltage in rated voltage ±10% range | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |||
Degree of protection | IP66 (IEC) | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
Weight (packed state) | Approx. 70 g | |||
Materials | Case, Cover | Heat-resistant ABS | ||
Cable clamp | NBR | |||
Accessories | Two bands, Four slip-proof tubes, Instruction manual |
*Stable detection will not be possible in the following cases. Confirm detection capability with the Sensor installed before actual application.
1. If the specific inductive capacity or the specific electric conductivity of the liquid is too low, the liquid position may not be detected since this sensor is a capacitive sensor.
2. If the quantity of liquid is too low or the change in quantity is too low in comparison to the change in liquid level because the pipe is too thin or the walls of the pipe are too thick.
3. If there is a viscous film on the inner pipe wall, large quantities of foam or air bubbles, or excessive buildup of dirt on the inner pipe wall
Le produit ne peut pas être utilisé normalement à cause de problèmes de qualité dans la période de garantie
Les marchandises sont endommagées pendant le transport
Si un retour est requis, les frais de retour seront payés par nous
L’acheteur enverra un courriel au personnel du service clientèle pour décrire les problèmes et fournir les documents d’attestation(les photos, les captures d’écran ou les vidéos claires)
Nous examinerons les problèmes dans un délai d’un à trois journées de travail. Pour ceux qui répondent aux exigences, nous fournirons un remplacement gratuit ou un remboursement dans un délai d’un à deux journées de travail
Si les marchandises doivent être retournées, nous payons les frais d'expédition de retour
E2K-L26MC1 Proximity Switch NEW
Gross Weight | 0.07 |
---|