Skype.me! Live Chat FAQ

Cerca nel Sito

Carrello 0 articoli

D4C-1201 Photoelectric Switch NEW

 44,18

D4C-1201 OMRON Photoelectric Switch NEW

Scheda dati D4C-1201 Photoelectric Switch NEW

OMRON Photoelectric Switch D4C-1201

Product Description:

Degree of protection

IP67

Durability *1

Mechanical *3

10,000,000 operations min.

Electrical *2

200,000 operations min. (5 A at 125 VAC, resistive load)

Operating speed

0.1 mm/s to 0.5 m/s (in case of plunger)

1 mm/s to 1 m/s (in case of roller lever)

Operating

Mechanical

120 operations/min

frequency

Electrical

30 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 M Ω min. (at 500 VDC)

Contact resistance (initial)

250 m Ω max. (initial value with 2-m VCTF cable)

300 m Ω max. (initial value with 3-m VCTF cable)

400 m Ω max. (initial value with 5-m VCTF cable)

Dielectric

Between terminals of the same polarity

1,000 VAC, 50/60 Hz for 1 min

strength

Between current-carrying metal part

1,500 VAC, 50/60 Hz for 1 min

 

and ground

Uimp: 2.5 kV (EN60947-5-1)

 

Between each terminal and non-current-

1,500 VAC, 50/60 Hz for 1 min

 

carrying metal part,

Uimp: 2.5 kV (EN60947-5-1)

Rated insulation voltage (Ui)

300 V (EN60947-5-1) *5

Pollution degree (operating environment)

3 (EN60947-5-1)

Short-circuit protective device (SCPD)

10 A fuse type gI or gG (IEC60269)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional enclosed thermal current (I the)

5 A, 4 A, 0.5 A (EN60947-5-1)

Protection against electric shock

Class I (with grounding wire) *6

Vibration

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *4

resistance

Shock

Destruction

1,000 m/s2 min.

resistance

Malfunction

500 m/s2 min. *4

Ambient operating temperature

-10 ° C to +70 ° C (with no icing)

Ambient operating humidity

35% to 95%RH

Weight

With 3-m VCTF cable: 360 g

With 5-m VCTF cable: 540 g

Note:The above figures are initial values.

*1.The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.

*2.Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)

*3.Outdoor specifications: 500,000 operations min.

*4.Excluding Plastic Rods.

*5.Pre-wired models: 250 V

*6.Pre-wired models: class III

 

 

loading...
Nelle seguenti circostanze, saremo spediti di nuovo gratis o il rimborso completo

Durante il periodo di garanzia, non può essere utilizzato per la qualità del prodotto

E' stato danneggiato durante il trasporto delle merci

Le merci causato da ragioni non sono stati consegnati in tempo


Il processo di spedire di nuovo o rimborso completo

Gli acquirenti spedire al nostro servizio clienti([email protected]) descrizione, e forniscono la certificazione dei materiali (foto, immagini o video)

Esaminare il problema in 1 - 3 giorni lavorativi e il rimborso sarà effettuato entro 1 - 2 giorni lavorativi per il rispetto dei requisiti

Se è richiesto un reso, le spese di spedizione per il reso saranno a nostro carico

D4C-1201 Photoelectric Switch NEW

Gross Weight 0.2