TL-W5MC2 OMRON Proximity Switch NEW
データシート | TL-W5MC2 Proximity Switch NEW |
OMRON Proximity Switch TL-W5MC2
Product Description:
Only 6 mm thick yet provides a sensing distance of 3 mm (TL-W3MC1).
Aluminum die-cast models also available.
Specifications:
Model | TL-W1R5MC1 | TL-W3MC[] | TL-W5MC[] | TL-W5E1 | TL-W20ME1 | |
TL-W5E2 | TL-W20ME2 | |||||
TL-W5F1 |
| |||||
TL-W5F2 |
| |||||
Sensing distance | 1.5 mm ±10% | 3 mm ±10% | 5 mm ±10% | 20 mm ±10% | ||
Set distance | 0 to 1.2 mm | 0 to 2.4 mm | 0 to 4 mm | 0 to 16 mm | ||
Differential travel | 10% max. of sensing distance | 1% to 15% of sensing | ||||
distance | ||||||
Detectable object | Ferrous metal | |||||
(The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) | ||||||
Standard sensing object | Iron, | Iron, | Iron, | Iron, | ||
8 × 8 × 1 mm | 12 × 12 × 1 mm | 18 × 18 × 1 mm | 50 × 50 × 1 mm | |||
Response frequency | 1 kHz min. | 600 Hz min. | 500 Hz min. | 300 Hz min. | 40 Hz min. | |
Power supply voltage | 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | 12 to 24 VDC (10 to | 12 to 24 VDC | |||
(operating voltage | 30 VDC), ripple (p-p): | (10 to 30 VDC), | ||||
range) | 20% max. | ripple (p-p): 10% max. | ||||
Current consumption | 15 mA max. at 24 VDC (no-load) | 10 mA max. | 15 mA max. at 24 | 8 mA at 12 VDC, | ||
VDC (no-load) | 15 mA at 24 VDC | |||||
Control | Load | NPN open collector | NPN open collector | 200 mA | 100 mA max. | |
output | current | 100 mA max. at 30 VDC max. | 50 mA max. at 12 VDC | at 12 VDC | ||
|
|
| (30 VDC max.) | 200 mA max. | ||
|
|
| 100 mA max. at 24 VDC | at 24 VDC | ||
|
|
| (30 VDC max.) |
| ||
| Residual | 1 V max. (under load current of 100 | 1 V max. (under load | 2 V max. (under load | 1 V max. (under load | |
| voltage | mA with cable length of 2 m) | current of 50 mA with | current of 200 mA with | current of 200 mA with | |
|
|
| cable length of 2 m) | cable length of 2 m) | cable length of 2 m) | |
Indicators | Detection indicator (red) | |||||
Operation mode | NO | C1 Models: NO | E1/F1 Models: NO | |||
(with sensing object | C2/B2 Models: NC | E2/F2 Models: NC | ||||
approaching) | Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. | |||||
Protection circuits | Reverse polarity protection, Surge suppressor | |||||
Ambient temperature | Operating/Storage: -25 to 70°C (with no icing or condensation) * | |||||
range | ||||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||||
Voltage influence | ±2.5% max. of sensing distance at | ±2.5% max. of sensing | ±2.5% max. of sensing distance at rated voltage | |||
rated voltage in the rated voltage | distance at rated voltage | in the rated voltage ±10% range | ||||
±10% range | in the rated voltage |
| ||||
| ±20% range |
| ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | Destruction: 500 m/s2 | ||||
10 times each in X, Y, | ||||||
and Z directions | ||||||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant * | |||||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||||
Weight (packed state) | Approx. 30 g | Approx. 45 g | Approx. 70 g | Approx. 180 g | ||
Materials | Case | Heat-resistant ABS | Aluminum die-cast | Heat-resistant ABS | ||
Sensing | Heat-resistant ABS | |||||
surface | ||||||
Accessories | Mounting Bracket, | Instruction manual | ||||
Instruction manual |
For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.
Product cannot use in warranty period because of product quality problems
Product is damaged in transit
Product is not delivered in time because of our reason

Buyers send an email to our customer service([email protected]) to describe the problem, and to provide evidence (clear photos, screenshots, or video)
We will check the problem in 1 working days. For those meet the requirements, free reissue or full refund will be made within 1 working days
If a return is required, the return shipping fee will be paid by us
TL-W5MC2 Proximity Switch NEW
Gross Weight | 0.05 |
---|