US$ 45.98

D4C-1224 OMRON Travel Switch NEW

Data Sheet D4C-1224 Travel Switch NEW

 

OMRON Travel Switch D4C-1224      

Product Description:

Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)

Sealing characteristics that meet IEC IP67 degree of protection.

Triple-sealed construction:

Plunger section sealed via nitrile rubber packing seal and diaphragm; switch section sealed via nitrile rubber cap; cable entrance sealed via encapsulating material.

Cable lengths of 3 and 5 m available on standard models. Models also available with UL and CSA-certified cables.

Multiple mounting possible with Switches with Plungers.

Models with red LED indicators added to series for easy confirmation of operation. (Set by default to light for non-operation.)

VCTF oil-resistant cables with CE marking. (Applicable only to standard models.)  

Specifications:

Degree of protection

IP67

Durability *1

Mechanical *3

10,000,000 operations min.

Electrical *2

200,000 operations min. (5 A at 125 VAC, resistive load)

Operating speed

0.1 mm/s to 0.5 m/s (in case of plunger)

1 mm/s to 1 m/s (in case of roller lever)

Operating

Mechanical

120 operations/min

frequency

Electrical

30 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 M Ω min. (at 500 VDC)

Contact resistance (initial)

250 m Ω max. (initial value with 2-m VCTF cable)

300 m Ω max. (initial value with 3-m VCTF cable)

400 m Ω max. (initial value with 5-m VCTF cable)

Dielectric

Between terminals of the same polarity

1,000 VAC, 50/60 Hz for 1 min

strength

Between current-carrying metal part

1,500 VAC, 50/60 Hz for 1 min

 

and ground

Uimp: 2.5 kV (EN60947-5-1)

 

Between each terminal and non-current-

1,500 VAC, 50/60 Hz for 1 min

 

carrying metal part,

Uimp: 2.5 kV (EN60947-5-1)

Rated insulation voltage (Ui)

300 V (EN60947-5-1) *5

Pollution degree (operating environment)

3 (EN60947-5-1)

Short-circuit protective device (SCPD)

10 A fuse type gI or gG (IEC60269)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional enclosed thermal current (I the)

5 A, 4 A, 0.5 A (EN60947-5-1)

Protection against electric shock

Class I (with grounding wire) *6

Vibration

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *4

resistance

Shock

Destruction

1,000 m/s2 min.

resistance

Malfunction

500 m/s2 min. *4

Ambient operating temperature

-10 ° C to +70 ° C (with no icing)

Ambient operating humidity

35% to 95%RH

Weight (D4C-1202)

With 3-m VCTF cable: 360 g

With 5-m VCTF cable: 540 g

 

Note:The above figures are initial values.

*1.The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.

*2.Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)

*3.Outdoor specifications: 500,000 operations min.

*4.Excluding Plastic Rods.

*5.Pre-wired models: 250 V

*6.Pre-wired models: class III

 

loading...
في الحالات التالية ، سنقوم بإعادة إصدار مجانية أو استرداد كامل للمبلغ المدفوع:

المنتج لا يمكن استخدامه في فترة الضمان بسبب مشاكل جودة المنتج

المنتج تالف أثناء الشحن

لم يتم تسليم المنتج في الوقت المحدد بسبب سبب من أسبابنا


إجراء إعادة الإصدار المجاني أو استرداد الكامل:

يرسل المشترون بريدًا إلكترونيًا إلى خدمة العملاء لدينا لوصف المشكلة وتقديم الأدلة (صور واضحة أو لقطات شاشة أو فيديو).

سنتحقق من المشكلة في يوم عمل واحد. للحالات المؤهلة ، سنقوم بتقديم استبدال مجاني أو استرداد كامل في غضون يومي عمل واحد إلى يومين.

إذا كانت هناك حاجة للإرجاع ، فسيتم دفع رسوم شحن الإرجاع من قبلنا.

D4C-1224 Travel Switch NEW

Gross Weight 0.25
credit card