E2E-X8MD1S-Z OMRON Proximity Switch NEW
Datablad | E2E-X8MD1S-Z Proximity Switch NEW |
Product Description:
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent mutual interference.
Superior environment resistance with standard cable made of oilresistant PVC and sensing surface made of material that resists cutting oil.
Specifications:
Size | M8 | M12 | M18 | M30 | |||||
Shielded | Shielded | Unshielded | Shielded | Unshielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E- | E2E- | E2E- | E2E- | E2E- | E2E- | E2E- | E2E- | |
X2D[] | X4MD[] | X3D[] | X8MD[] | X7D[] | X14MD[] | X10D[] | X20MD[] | ||
Sensing distance | 2 mm ±10% | 4 mm ±10% | 3 mm ±10% | 8 mm ±10% | 7 mm ±10% | 14 mm ±10% | 10 mm ±10% | 20 mm ±10% | |
Set distance *1 | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 2.4 mm | 0 to 6.4 mm | 0 to 5.6 mm | 0 to 11.2 mm | 0 to 8 mm | 0 to 16 mm | |
Differential travel | 15% max. of sensing distance | 10% max. of sensing distance | |||||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Data Sheet.) | ||||||||
Standard sensing | Iron, 8 × | Iron, 20 × | Iron, 12 × | Iron, 30 × | Iron, 18 × | Iron, 30 × 30 × 1 mm | Iron, 54 × | ||
object | 8 × 1 mm | 20 × 1 mm | 12 × 1 mm | 30 × 1 mm | 18 × 1 mm | 54 × 1 mm | |||
Response frequency | 1.5 kHz | 1 kHz | 0.8 kHz | 0.5 kHz | 0.4 kHz | 0.1 kHz | |||
*2 | |||||||||
Power supply voltage | 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | ||||||||
(operating voltage | |||||||||
range) | |||||||||
Leakage current | 0.8 mA max. | ||||||||
Control | Load | 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models | |||||||
output | current | ||||||||
| Residual | 3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.) | |||||||
| voltage | ||||||||
| *3 | ||||||||
Indicators | D1 Models: Operation indicator (red) and setting indicator (green) | ||||||||
D2 Models: Operation indicator (red) | |||||||||
Operation mode | D1 Models: NO | ||||||||
(with sensing object | D2 Models: NC | ||||||||
approaching) | Refer to Data Sheet. | ||||||||
Diagnostic output | 0.3 to 1 s | ||||||||
delay | |||||||||
Protection circuits | Surge suppressor, Load short-circuit protection (for control and diagnostic output) | ||||||||
Ambient | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||||||
temperature range | |||||||||
Ambient | Operating/storage: 35% to 95% (with no condensation) | ||||||||
humidity range | |||||||||
Temperature | ±15% max. of sensing | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||||||
influence | distance at 23°C in the | ||||||||
| temperature range of -25 | ||||||||
| to 70°C | ||||||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||||||
Dielectric strength | 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case | ||||||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||||||
Shock resistance | Destruction: 500 m/s2 | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | |||||||
10 times each in X, Y, and | |||||||||
Z directions | |||||||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant | ||||||||
Connector Models: IEC 60529 IP67 | |||||||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m) | ||||||||
Weight | Pre-wired | Approx. 60 g | Approx. 70 g | Approx. 130 g | Approx. 175 g | ||||
(packed | Models | ||||||||
state) | Pre-wired | --- | Approx. 40 g | Approx. 70 g | Approx. 110 g | ||||
| Connector | ||||||||
| Models | ||||||||
| Connector | Approx. 15 g | Approx. 25 g | Approx. 40 g | Approx. 90 g | ||||
| Models | ||||||||
Materi- | Case | Stainless steel (SUS303) | Nickel-plated brass | ||||||
als | Sensing | PBT | |||||||
| surface | ||||||||
| Clamping | Nickel-plated brass | |||||||
| nuts | ||||||||
| Toothed | Zinc-plated iron | |||||||
| washer | ||||||||
Accessories | Instruction manual |
*1.Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2.The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3.The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to Data Sheet for details.)
Produktet kan ikke bruges i garantiperioden på grund af produktkvalitetsproblemer
Produktet er beskadiget under transport
Produktet er ikke leveret til tiden på grund af vores skyld
Køberne sender en e-mail til vores kundeservice for at beskrive problemet og give beviser (klare fotos, skærmbilleder eller video)
Vi vil undersøge problemet inden for 1 arbejdsdag. For kvalificerede tilfælde vil vi give en gratis ombytning eller fuld refusion inden for 1-2 arbejdsdage
Hvis der kræves en retur, vil returforsendelsesgebyret blive betalt af os
E2E-X8MD1S-Z Proximity Switch NEW
Gross Weight | 0.1 |
---|