E2K-F10MC1 Omron Flat Proximity Sensor NEW
Data Sheet | E2K-F10MC1 Flat Proximity Sensor NEW |
Product Description:
DC 3-Wire Model , Flat Type , Unshielded , Sensing Distance 10mm , Operation Mode NO.
Specifications:
Type | Unshielded |
Sensing method | Capacitive type |
Sensing distance | 10 mm -10% to +10% |
Setting distance | 0 to 7.5 mm |
Differential distance | 15% Max. of sensing distance |
Sensing object | Conductor and dielectrics |
Standard sensing object | With grounded metal 50*50*1mm |
Response frequency | DC: 100 Hz (average) |
Power supply voltage | 12 to 24 VDC (ripple(p-p) :10% Max.) |
Operating voltage range | 10 to 30 VDC |
Current consumption | 10 mA Max. (at 24VDC) |
Control output (Output type) | NPN open collector output |
Control output (Switching capacity) | 0 to 100 mA (at 30VDC) |
Control output (Residual voltage) | (DC) 1.5 V Max. (under load current with cable length of 2m) |
Indicator | Detection indicator(red) |
Operation mode | NO |
Protective circuit | Surge suppressor |
Power supply reverse polarity protection | |
Standard or Different frequency | Standard |
Ambient temperature | Operating: -10 to 55 CEL |
Storage: -10 to 55 CEL | |
(with no icing or condensation) | |
Ambient humidity | Operating: 35 to 95 %RH |
Storage: 35 to 95 %RH | |
(with no condensation) | |
Temperature influence | +-15% Max. of sensing distance in temperature range of -10 to +55CEL |
(As the basis for sensing distance of 23CEL) | |
Voltage influence | +-2.5% Max. of sensing distance in rated voltage range +-10%. (As the basis for sensing distance at standard power voltage) |
Insulation resistance | 50 M OHM Min. at 500VDC between charged parts and the case |
Dielectric strength | 500 VAC 50/60 Hz for 1 minute between charged parts and the case |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance | 500m/s2 for 3 times each in X, Y, and Z directions |
Degree of protection | IEC60529: IP66 |
Applicable standard (EC Directive (Low Voltage Directive)) | EN60947-1 |
EN60947-5-2 | |
Applicable standard (EC Directive (EMC Directive)) | EMI: EN60947-5-2 |
Emission Enclosure: CISPR11 Group 1 class A | |
EMS: EN60947-5-2 | |
Immunity ESD: IEC61000-4-2 | |
Immunity RF-interference: IEC61000-4-3 | |
Immunity Conducted Disturbance: IEC61000-4-6 | |
Immunity Burst: IEC61000-4-4 | |
CE marking: Equipped | |
Applicable standard (CCC mark) | Not equipped |
Connection method | Pre-wired models (Cable length: 2 m) |
Weight (Packed state) | approx. 35 g |
Material (case) | Heat-resistant ABS resin |
Material (sensing surface) | Heat-resistant ABS resin |
Accessories | Instruction manual |
המוצר אינו יכול להשתמש בתקופת האחריות בגלל בעיות איכות המוצר
המוצר נפגם במשלוח
המוצר לא נמסר בזמן בשל סיבתנו
הקונים שולחים אימייל לשירות הלקוחות שלנו כדי לתאר את הבעיה ולספק הוכחות (תמונות ברורות, צילומי מסך או וידאו)
אנו נבדוק את הבעיה ביום עסקים אחד. למקרים המתאימים, נספק החלפה חינם או החזר מלא בתוך 1 ימי עסקים
אם נדרשה החזרה, נשלם את דמי משלוח ההחזרה
E2K-F10MC1 Flat Proximity Sensor NEW
Gross Weight | 0.04 |
---|