S8JX-G05024CD OMRON Switching Power Supply NEW
Adatlap | S8JX-G05024CD Switching Power Supply NEW |
Product Description:
Flexible Selection of Reliability and Ease of Operation with the S8JX. New Models with Harmonic Current Suppression for a Broader Lineup.
Specifications:
Input specification | 100 to 240 V input | ||||
Power ratings *1 | 15 W | 35 W | |||
Efficiency | 68% min. | 73% min. | |||
Input | Voltage *2 | 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *9) | |||
Frequency *2 | 50/60 Hz (47 to 450 Hz) | ||||
Current *3 | 100 V input | 0.4 A max. | 1 A max. | ||
200 V input | 0.25 A max. | 0.6 A max. | |||
Harmonic current emissions | --- | ||||
Leakage | 100 V input | 0.5 mA max. | |||
current *3 | 200 V input | 1 mA max. | |||
Inrush current | 100 V input | 20 A max. | |||
(for a cold | |||||
start at 25 °C) | |||||
*3 | 200 V input | 40 A max. | |||
Output | Voltage adjustment range *5 | - 10% to 15% (with V. ADJ) (48-V models: ± 10%) | |||
*4 | Ripple *3 | 2% (p-p) max. | |||
| Input variation influence | 0.4% max. with AC input voltage | |||
| Load variation influence | 0.8% max. (0 to 100% load, rated input voltage) | |||
| Temperature variation influence | 0.05%/ ° C max. (at rated input and output) | |||
| Startup time | 500 ms max. (up to 90% of output voltage at rated input and output) | |||
| Hold time *3 | 20 ms min. | |||
Additional | Overload protection *6 | 105% to 175% of rated load current, voltage drop, intermittent, automatic reset | |||
functions | Overvoltage protection *7 | Yes | |||
| Overheat protection | No | |||
| Parallel operation | No (However, backup operation is possible; external diodes required.) | |||
| Series operation | Yes (For up to two Power Supplies; external diodes required.) | |||
| Protective circuit operation indicator | No | |||
Other | Ambient operating temperature | Refer to the derating curve in Engineering Data on Data Sheet (with no icing or | |||
condensation). | |||||
Storage temperature | - 25 to 65 ° C (with no icing or condensation) | ||||
Ambient operating humidity | 25% to 85% (Storage humidity: 25% to 90%) | ||||
Dielectric strength | 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) | ||||
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) | |||||
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) | |||||
Insulation resistance | 100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC | ||||
Vibration resistance | 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions | ||||
Shock resistance | 150 m/s2 , 3 times each in ± X, ± Y, ± Z directions | ||||
Output indicator | Yes (Color: Green) | ||||
EMI | Conducted | Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9 | |||
Emissions | |||||
Radiated Emissions | Conforms to EN 55011 Group 1 Class A *9 | ||||
EMS | Electrostatic | Conforms to EN61000-4-2 | |||
Discharge | |||||
Radiated | Conforms to EN61000-4-3 | ||||
Electromagnetic | |||||
Field | |||||
Electrical Fast | Conforms to EN61000-4-4 | ||||
Transient/Burst | |||||
Surge | Conforms to EN61000-4-5 | ||||
Conducted | Conforms to EN61000-4-6 | ||||
Disturbance | |||||
Voltage Dips/ | Conforms to EN61000-4-11 | ||||
Short Interruptions | |||||
Approved standards *9 | UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition) | ||||
cUL Listed: CSA C22.2 No.107.1 | |||||
cUR: CSA C22.2 No. 60950-1 | |||||
EN/VDE: EN50178 (= VDE 0160) Over voltage category III, EN 60950-1 (= VDE 0805 | |||||
Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) | |||||
SEMI | SEMI F47-0200 (200-VAC input) | ||||
Weight *8 | 250 g max. | ||||
Input specification | 100 to 240 V input | ||||
Power ratings *1 | 50 W | 100 W | |||
Efficiency | 5 V Models | 76% min. | 76% min. | ||
12 V Models | 81% min. | 81% min. | |||
24 V Models | 83% min. | 83% min. | |||
48 V Models | 82% min. | 83% min. | |||
Input | Voltage *2 | 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *9) | |||
Frequency *2 | 50/60 Hz (47 to 450 Hz) | ||||
Current *3 | 100 V input | 1.4 A max. | 2.5 A max. | ||
200 V input | 0.8 A max. | 1.5 A max. | |||
Harmonic current emissions | --- | ||||
Leakage | 100 V input | 0.5 mA max. | |||
current *3 | 200 V input | 1 mA max. | |||
Inrush current | 100 V input | 20 A max. | |||
(for a cold | |||||
start at 25 °C) | |||||
*3 | 200 V input | 40 A max. | |||
Output | Voltage adjustment range *5 | - 10% to 15% (with V. ADJ) (48-V models: ± 10%) | |||
*4 | Ripple *3 | 2% (p-p) max. | |||
| Input variation influence | 0.4% max. with AC input voltage | |||
| Load variation influence | 0.8% max. (0 to 100% load, rated input voltage) | |||
| Temperature variation influence | 0.05%/ ° C max. (at rated input and output) | |||
| Startup time | 500 ms max. (up to 90% of output voltage at rated input and output) | |||
| Hold time *3 | 20 ms min. | |||
Additional | Overload protection *6 | 105% to 175% of rated load current, voltage drop, intermittent, automatic reset | |||
functions | Overvoltage protection *7 | Yes | |||
| Overheat protection | No | |||
| Parallel operation | No (However, backup operation is possible; external diodes required.) | |||
| Series operation | Yes (For up to two Power Supplies; external diodes required.) | |||
| Protective circuit operation indicator | No | |||
Other | Ambient operating temperature | Refer to the derating curve in Engineering Data on Data Sheet (with no icing or | |||
condensation). | |||||
Storage temperature | - 25 to 65 ° C (with no icing or condensation) | ||||
Ambient operating humidity | 25% to 85% (Storage humidity: 25% to 90%) | ||||
Dielectric strength | 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) | ||||
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) | |||||
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) | |||||
Insulation resistance | 100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC | ||||
Vibration resistance | 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions | ||||
Shock resistance | 150 m/s2 , 3 times each in ± X, ± Y, ± Z directions | ||||
Output indicator | Yes (Color: Green) | ||||
EMI | Conducted | Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9 | |||
Emissions | |||||
Radiated Emissions | Conforms to EN 55011 Group 1 Class A *9 | ||||
EMS | Electrostatic | Conforms to EN61000-4-2 | |||
Discharge | |||||
Radiated | Conforms to EN61000-4-3 | ||||
Electromagnetic | |||||
Field | |||||
Electrical Fast | Conforms to EN61000-4-4 | ||||
Transient/Burst | |||||
Surge | Conforms to EN61000-4-5 | ||||
Conducted | Conforms to EN61000-4-6 | ||||
Disturbance | |||||
Voltage Dips/Short | Conforms to EN61000-4-11 | ||||
Interruptions | |||||
Approved standards *9 | UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition) | ||||
cUL Listed: CSA C22.2 No.107.1 | |||||
cUR: CSA C22.2 No. 60950-1 | |||||
EN/VDE: EN50178 (= VDE 0160) Over voltage category III, EN 60950-1 (= VDE 0805 | |||||
Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) | |||||
SEMI | SEMI F47-0200 (200-VAC input) | ||||
Weight *8 | 300 g max. | 550 g max. | |||
Input specification | 100/200 V switchable | 100 to 240 V input | |||
Power ratings *1 | 150 W at 5 V | 150 W at 12 V | 150 W at 24 or 48 V | ||
Efficiency | 5 V Models | 78% min. | --- | --- | |
12 V Models | --- | 79% min. | --- | ||
24 V Models | --- | --- | 86% min. | ||
48 V Models | --- | --- | 85% min. | ||
Input | Voltage *2 | Switchable between 100 to 120 VAC | 100 to 240 VAC | ||
(allowable range: 85 to 132 VAC) and | (allowable range: 85 to 264 VAC, | ||||
200 to 240 VAC (allowable range: 170 | 80 to 370 VDC *9) | ||||
to 264 VAC). |
| ||||
Frequency *2 | 50/60 Hz (47 to 450 Hz) | ||||
Current *3 | 100 V input | 3.5 A max. | 3.6 A max. | 3.5 A max. | |
200 V input | 2.1 A max. | 2.2 A max. | 2.1 A max. | ||
Harmonic current emissions | --- | ||||
Leakage | 100 V input | 0.5 mA max. | |||
current *3 | 200 V input | 1 mA max. | |||
Inrush current | 100 V input | 20 A max. | |||
(for a cold | |||||
start at 25 °C) | |||||
*3 | 200 V input | 40 A max. | |||
Output | Voltage adjustment range *5 | - 10% to 15% (with V. ADJ) (48-V models: ± 10%) | |||
*4 | Ripple *3 | 2% (p-p) max. | |||
| Input variation influence | 0.4% max. (with AC input voltage) | |||
| Load variation influence | 0.8% max. (0 to 100% load, rated input voltage) | |||
| Temperature variation influence | 0.05%/ ° C max. (at rated input and output) | |||
| Startup time | 500 ms max. (up to 90% of output voltage at rated input and output) | |||
| Hold time *3 | 20 ms min. | |||
Additional | Overload protection *6 | 105% to 175% of rated load current, | 105% to 175% of rated load current, | ||
functions | voltage drop, automatic reset | voltage drop, intermittent, automatic | |||
|
| reset | |||
| Overvoltage protection *7 | Yes | |||
| Overheat protection | No | |||
| Parallel operation | No (However, backup operation is possible; external diodes required.) | |||
| Series operation | Yes (For up to two Power Supplies; external diodes required.) | |||
| Protective circuit operation indicator | No | |||
Other | Ambient operating temperature | Refer to the derating curve in Engineering Data on Data Sheet (with no icing or | |||
condensation). | |||||
Storage temperature | - 25 to 65 ° C (with no icing or condensation) | ||||
Ambient operating humidity | 25% to 85% (Storage humidity: 25% to 90%) | ||||
Dielectric strength | 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) | ||||
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) | |||||
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) | |||||
Insulation resistance | 100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC | ||||
Vibration resistance | 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions | ||||
Shock resistance | 150 m/s2 , 3 times each in ± X, ± Y, ± Z directions | ||||
Output indicator | Yes (Color: Green) | ||||
EMI | Conducted | Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9 | |||
Emissions | |||||
Radiated Emissions | Conforms to EN 55011 Group 1 Class A *9 | ||||
EMS | Electrostatic | Conforms to EN61000-4-2 | |||
Discharge | |||||
Radiated | Conforms to EN61000-4-3 | ||||
Electromagnetic | |||||
Field | |||||
Electrical Fast | Conforms to EN61000-4-4 | ||||
Transient/Burst | |||||
Surge | Conforms to EN61000-4-5 | ||||
Conducted | Conforms to EN61000-4-6 | ||||
Disturbance | |||||
Voltage Dips/Short | Conforms to EN61000-4-11 | ||||
Interruptions | |||||
Approved standards *9 | UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition) | ||||
cUL Listed: CSA C22.2 No.107.1 | |||||
cUR: CSA C22.2 No. 60950-1 | |||||
EN/VDE: EN50178 (= VDE 0160), Over voltage category III, EN 60950-1 (= VDE 0805 | |||||
Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514)) | |||||
SEMI | --- | SEMI F47-0200 (200-VAC input) | |||
Weight *8 | 800 g max. | 700 g max. | 600 g max. |
*1.When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection in Data Sheet.
*3.Rated input voltage: 100 or 200 VAC at 100% load.
*4.Output characteristics: Specified at power supply output terminals.
*5.If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*6.For details, refer to Overload Protection in Data Sheet.
*7.To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON.
*8.The weight indicated is for Front-mounting, Open-frame Power Supply.
*9.The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
A termék nem használható a garanciális időszakban a termék minőségi problémái miatt
A termék szállítás közben megsérült
A termék nem érkezett meg időben azért, mert mi vagyunk az ok
A vásárlók e-mailt küldenek ügyfélszolgálatunkra, hogy leírják a problémát, és bizonyítékokat nyújtsanak (tisztán látható fényképek, képernyőképek vagy videók)
Ellenőrizzük a problémát 1 munkanapon belül. A jogos esetekben 1-2 munkanapon belül ingyenes csere vagy teljes visszatérítés biztosítunk
Ha visszaküldés szükséges, a visszaküldési díjat mi fizetjük
S8JX-G05024CD Switching Power Supply NEW
Gross Weight | 1 |
---|