VTE18-4N8240 SICK Photoelectric switch NEW
Adatlap | VTE18-4N8240 SICK Photoelectric switch NEW |
Product Description:
Energetic scanner, also with large scanning distances for standard applications
3 scanning distance options:
SD 1 = 200 mm
SD 2 = 400 mm
SD 3 = 800 mm
Optionally VT 18-3 in 3-line model or VT 18-4 with light/dark control line
Many other options
Specifications:
Housing | Straight |
Angled, 90° | |
VTE 18 Scanning distance 200 mm
| |
Scanning distance, max. typical1) | 3...200 mm |
Scanning distance1) | 3...170 mm |
Light spot diameter | Approx. 10 mm at a dist. of 200 mm |
VTE 18 Scanning distance 400 mm | |
Scanning distance, max. typical1) | 5...400 mm |
Scanning distance1) | 5...350 mm |
Light spot diameter | Approx. 20 mm at a dist. of 400 mm |
VTE 18 Scanning distance 800 mm | |
Scanning distance, max. typical1) | 10...800 mm |
Scanning distance1) | 10...700 mm |
Light spot diameter | Approx. 40 mm at a dist. of 800 mm |
Sensitivity adjustable (optional) | Potentiometer 270° |
Light source2), light type | LED, infrared light |
Angle of dispersion of sender | 2.8° |
Supply voltage VS | 10...30 V DC3) |
Ripple4) | ±10 % |
Current consumption5) | ≤ 30 mA |
Switching outputs (optional) | PNP/NPN; open collector: Q |
Switching mode | Q, light-/dark-switching |
| Q, light-switching |
via control wire L/D6) | Q, light-/dark-switching |
| +VS=light-switching |
| 0 V = dark-switching |
Output current IA max. | 100 mA |
Response time7) | ≤ 2 ms |
Max. switching frequency8) | 250/s |
Connection types | |
cable 2 m9) | PVC, 3 x 0.14 mm2, l3.1 mm |
| PVC, 4 x 0.14 mm2, l5mm |
plug | 4 pin, M12 |
VDE protection class10) | 回 |
Circuit protection11) | A, B, C, D |
Enclosure rating | IP 67 |
Ambient temperature TA | – 25 °C...+ 70 °C |
Weight | |
metal housing | Approx. 120 g |
plastic housing | Approx. 100 g |
Housing material | |
metal housing | Nickel-plated brass; PBT/PC |
plastic housing | PBT/PC |
optic | PMMA |
1) Object with 90 % reflectance (referred to standard white DIN 5033)
3) Limit values
4) Must be within VS tolerances
5) Without load
6) Control wire open: NPN: light-switching PNP: dark-switching
7) With resistive load
8) With light/dark ratio 1:1
9) Do not bend below 0 °C
10) Reference voltage 50 V DC
11) A = Vs connections reverse-polarity protected
B = Inputs/outputs reverse-polarity protected
C = Interference suppression
D = Outputs overcurrent and shortcircuit protected
A termék nem használható a garanciális időszakban a termék minőségi problémái miatt
A termék szállítás közben megsérült
A termék nem érkezett meg időben azért, mert mi vagyunk az ok
A vásárlók e-mailt küldenek ügyfélszolgálatunkra, hogy leírják a problémát, és bizonyítékokat nyújtsanak (tisztán látható fényképek, képernyőképek vagy videók)
Ellenőrizzük a problémát 1 munkanapon belül. A jogos esetekben 1-2 munkanapon belül ingyenes csere vagy teljes visszatérítés biztosítunk
Ha visszaküldés szükséges, a visszaküldési díjat mi fizetjük
VTE18-4N8240 SICK Photoelectric switch NEW
Gross Weight | 0.12 |
---|