D4C-6220 OMRON Travel Switch NEW
Data Sheet | D4C-6220 Travel Switch NEW |
OMRON Travel Switch D4C-6220
Product Description:
Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and diaphragm; switch section sealed via nitrile rubber cap; cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models. Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy confirmation of operation. (Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking. (Applicable only to standard models.)
Specifications:
Degree of protection | IP67 | |
Durability *1 | Mechanical *3 | 10,000,000 operations min. |
Electrical *2 | 200,000 operations min. (5 A at 125 VAC, resistive load) | |
Operating speed | 0.1 mm/s to 0.5 m/s (in case of plunger) | |
1 mm/s to 1 m/s (in case of roller lever) | ||
Operating | Mechanical | 120 operations/min |
frequency | Electrical | 30 operations/min |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 M Ω min. (at 500 VDC) | |
Contact resistance (initial) | 250 m Ω max. (initial value with 2-m VCTF cable) | |
300 m Ω max. (initial value with 3-m VCTF cable) | ||
400 m Ω max. (initial value with 5-m VCTF cable) | ||
Dielectric | Between terminals of the same polarity | 1,000 VAC, 50/60 Hz for 1 min |
strength | Between current-carrying metal part | 1,500 VAC, 50/60 Hz for 1 min |
| and ground | Uimp: 2.5 kV (EN60947-5-1) |
| Between each terminal and non-current- | 1,500 VAC, 50/60 Hz for 1 min |
| carrying metal part, | Uimp: 2.5 kV (EN60947-5-1) |
Rated insulation voltage (Ui) | 300 V (EN60947-5-1) *5 | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Short-circuit protective device (SCPD) | 10 A fuse type gI or gG (IEC60269) | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (I the) | 5 A, 4 A, 0.5 A (EN60947-5-1) | |
Protection against electric shock | Class I (with grounding wire) *6 | |
Vibration | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *4 |
resistance | ||
Shock | Destruction | 1,000 m/s2 min. |
resistance | Malfunction | 500 m/s2 min. *4 |
Ambient operating temperature | -10 ° C to +70 ° C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight (D4C-1202) | With 3-m VCTF cable: 360 g | |
With 5-m VCTF cable: 540 g |
Note:The above figures are initial values.
*1.The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
*2.Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)
*3.Outdoor specifications: 500,000 operations min.
*4.Excluding Plastic Rods.
*5.Pre-wired models: 250 V
*6.Pre-wired models: class III
Product cannot use in warranty period because of product quality problems
Product is damaged in transit
Product is not delivered in time because of our reason
Buyers send an email to our customer service to describe the problem, and to provide evidence (clear photos, screenshots, or video)
We will check the problem in 1 working days. For eligible cases, we will provide a free replacement or full refund within 1-2 business days
If a return is required, the return shipping fee will be paid by us
D4C-6220 Travel Switch NEW
Gross Weight | 0.25 |
---|