Data Sheet D4C-6220 Travel Switch NEW

OMRON Travel Switch D4C-6220    

Product Description:

Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)

Sealing characteristics that meet IEC IP67 degree of protection.

Triple-sealed construction:

Plunger section sealed via nitrile rubber packing seal and diaphragm; switch section sealed via nitrile rubber cap; cable entrance sealed via encapsulating material.

Cable lengths of 3 and 5 m available on standard models. Models also available with UL and CSA-certified cables.

Multiple mounting possible with Switches with Plungers.

Models with red LED indicators added to series for easy confirmation of operation. (Set by default to light for non-operation.)

VCTF oil-resistant cables with CE marking. (Applicable only to standard models.)  

Specifications:

Degree of protection

IP67

Durability *1

Mechanical *3

10,000,000 operations min.

Electrical *2

200,000 operations min. (5 A at 125 VAC, resistive load)

Operating speed

0.1 mm/s to 0.5 m/s (in case of plunger)

1 mm/s to 1 m/s (in case of roller lever)

Operating

Mechanical

120 operations/min

frequency

Electrical

30 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 M Ω min. (at 500 VDC)

Contact resistance (initial)

250 m Ω max. (initial value with 2-m VCTF cable)

300 m Ω max. (initial value with 3-m VCTF cable)

400 m Ω max. (initial value with 5-m VCTF cable)

Dielectric

Between terminals of the same polarity

1,000 VAC, 50/60 Hz for 1 min

strength

Between current-carrying metal part

1,500 VAC, 50/60 Hz for 1 min

 

and ground

Uimp: 2.5 kV (EN60947-5-1)

 

Between each terminal and non-current-

1,500 VAC, 50/60 Hz for 1 min

 

carrying metal part,

Uimp: 2.5 kV (EN60947-5-1)

Rated insulation voltage (Ui)

300 V (EN60947-5-1) *5

Pollution degree (operating environment)

3 (EN60947-5-1)

Short-circuit protective device (SCPD)

10 A fuse type gI or gG (IEC60269)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional enclosed thermal current (I the)

5 A, 4 A, 0.5 A (EN60947-5-1)

Protection against electric shock

Class I (with grounding wire) *6

Vibration

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *4

resistance

Shock

Destruction

1,000 m/s2 min.

resistance

Malfunction

500 m/s2 min. *4

Ambient operating temperature

-10 ° C to +70 ° C (with no icing)

Ambient operating humidity

35% to 95%RH

Weight (D4C-1202)

With 3-m VCTF cable: 360 g

With 5-m VCTF cable: 540 g

 

Note:The above figures are initial values.

*1.The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.

*2.Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)

*3.Outdoor specifications: 500,000 operations min.

*4.Excluding Plastic Rods.

*5.Pre-wired models: 250 V

*6.Pre-wired models: class III

 

loading...
In the following cases, we will make a free reissue or full refund

Product cannot use in warranty period because of product quality problems

Product is damaged in transit

Product is not delivered in time because of our reason


Process of free reissue or full refund

Buyers send an email to our customer service to describe the problem, and to provide evidence (clear photos, screenshots, or video)

We will check the problem in 1 working days. For eligible cases, we will provide a free replacement or full refund within 1-2 business days

If a return is required, the return shipping fee will be paid by us


Buyers can apply for return or exchange within 90 days of receipt

D4C-6220 Travel Switch NEW

Gross Weight 0.25
credit card