D4C-1250 OMRON Travel Switch NEW
Datenblatt | D4C-1250 Travel Switch NEW |
OMRON Travel Switch D4C-1250
Product Description:
Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and diaphragm; switch section sealed via nitrile rubber cap; cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models. Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy confirmation of operation. (Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking. (Applicable only to standard models.)
Specifications:
Degree of protection | IP67 | |
Durability *1 | Mechanical *3 | 10,000,000 operations min. |
Electrical *2 | 200,000 operations min. (5 A at 125 VAC, resistive load) | |
Operating speed | 0.1 mm/s to 0.5 m/s (in case of plunger) | |
1 mm/s to 1 m/s (in case of roller lever) | ||
Operating | Mechanical | 120 operations/min |
frequency | Electrical | 30 operations/min |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 M Ω min. (at 500 VDC) | |
Contact resistance (initial) | 250 m Ω max. (initial value with 2-m VCTF cable) | |
300 m Ω max. (initial value with 3-m VCTF cable) | ||
400 m Ω max. (initial value with 5-m VCTF cable) | ||
Dielectric | Between terminals of the same polarity | 1,000 VAC, 50/60 Hz for 1 min |
strength | Between current-carrying metal part | 1,500 VAC, 50/60 Hz for 1 min |
| and ground | Uimp: 2.5 kV (EN60947-5-1) |
| Between each terminal and non-current- | 1,500 VAC, 50/60 Hz for 1 min |
| carrying metal part, | Uimp: 2.5 kV (EN60947-5-1) |
Rated insulation voltage (Ui) | 300 V (EN60947-5-1) *5 | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Short-circuit protective device (SCPD) | 10 A fuse type gI or gG (IEC60269) | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (I the) | 5 A, 4 A, 0.5 A (EN60947-5-1) | |
Protection against electric shock | Class I (with grounding wire) *6 | |
Vibration | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *4 |
resistance | ||
Shock | Destruction | 1,000 m/s2 min. |
resistance | Malfunction | 500 m/s2 min. *4 |
Ambient operating temperature | -10 ° C to +70 ° C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight (D4C-1202) | With 3-m VCTF cable: 360 g | |
With 5-m VCTF cable: 540 g |
Note:The above figures are initial values.
*1.The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
*2.Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)
*3.Outdoor specifications: 500,000 operations min.
*4.Excluding Plastic Rods.
*5.Pre-wired models: 250 V
*6.Pre-wired models: class III
Innerhalb von der Garantie aufgrund von Problemen mit der Produktqualität führt es dazu, dass das Produkt nicht verwendet werden kann
Die Ware wird während des Transports beschädigt
Das Produkt wurde aufgrund unseres Verschuldens nicht rechtzeitig geliefert.
Der Käufer sendet unserem Kundenservice eine E-Mail, um das Problem zu beschreiben und unterstützende Dokumente bereitzustellen (klares Foto, Screenshot oder Video)
Wir überprüfen das Problem innerhalb von 1-3 Werktagen. Wenn der Antrag gerechtet ist, wird innerhalb von 1-2 Tagen kostenloser Ersatz oder Rückerstattung arrangiert
Wenn eine Rücksendung erforderlich ist, wird die Rücksendegebühr von uns bezahlt
D4C-1250 Travel Switch NEW
Gross Weight | 0.25 |
---|