    Mount to bypass pipes.

    Fit a wide range of pipe diameters: 8 to 11 mm or 12 to 26 mm

    Built-in Amplifiers to save space.

    Specifications:

    Model

    E2K-L13MC1

    E2K-L26MC1

    Applicable pipes

    Materials

    Non-metal

    Size

    Diameter

    8 to 11 mm

    12 to 26 mm

    Thickness

    1 mm max.

    1.5 mm max.

    Detectable object

    Liquid *

    Repeat accuracy

    ±0.2 mm max.

    Differential travel

    0.6 to 5 mm

    0.3 to 3 mm

    (Reference value, varies with

    pipe size and liquid.)

    Power supply voltage

    12 to 24 VDC (10.8 to 30 VDC), ripple (p-p): 10% max.

    (operating voltage range)

    Current consumption

    12 mA max.

    Control output

    Load current

    100 mA max.

    Residual voltage

    1 V max. (Load current: 100 mA, Cable length: 2 m)

    Sensing liquid position

    Indented mark position (For details, refer to Datasheet)

    Indicators

    Detection indicator (orange)

    Ambient temperature range

    Operating: 0 to 55°C (with no icing or condensation), Storage: -10 to 65°C (with no icing or condensation)

    Ambient humidity range

    Operating/Storage: 25% to 85% (with no condensation)

    Temperature influence

    ±4 mm of detection level at 23°C in the temperature range of 0 to 55°C

    (with pure water or 20% saline solution)

    (±6 mm for E2K-L13MC1 with pure water and a pipe diameter of 8 mm)

    Voltage influence

    ±0.5 mm of detection level at the rated voltage in rated voltage ±10% range

    Insulation resistance

    50 MΩ min. (at 500 VDC) between current-carrying parts and case

    Dielectric strength

    500 VAC, 50/60 Hz for 1 min between current-carrying parts and case

    Vibration resistance

    Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

    Shock resistance

    Destruction: 500 m/s2 3 times each in X, Y, and Z directions

    Degree of protection

    IP66 (IEC)

    Connection method

    Pre-wired Models (Standard cable length: 2 m)

    Weight (packed state)

    Approx. 70 g

    Materials

    Case, Cover

    Heat-resistant ABS

    Cable clamp

    NBR

    Accessories

    Two bands, Four slip-proof tubes, Instruction manual

    *Stable detection will not be possible in the following cases. Confirm detection capability with the Sensor installed before actual application.

    1. If the specific inductive capacity or the specific electric conductivity of the liquid is too low, the liquid position may not be detected since this sensor is a capacitive sensor.

    2. If the quantity of liquid is too low or the change in quantity is too low in comparison to the change in liquid level because the pipe is too thin or the walls of the pipe are too thick.

    3. If there is a viscous film on the inner pipe wall, large quantities of foam or air bubbles, or excessive buildup of dirt on the inner pipe wall

     

    loading...
    14-Day Return Policy
    Customers have the right to withdraw from the contract within 14 days without providing any reason.
    The withdrawal period ends 14 days after the day you receive your order.
    Products must be returned in good condition, unused, and in their original packaging, except in cases of quality defects.
    Buyers must send the goods back within 14 days after notifying us.
    If your order includes multiple items delivered separately, the 14-day period begins when the last item is received.

    How to exercise the withdrawal right

    To exercise your 14-day withdrawal right, please contact us:
    Email:[email protected]
    Phone:+86 755-86211480

    You may use the model withdrawal form, but it is not mandatory.
    Please include:
    Your name
    Order number
    The product(s) you wish to return

    Return Address

    Please do not return any product without prior confirmation from our customer service.
    The confirmed return address (located in Shenzhen, China) will be provided after customer service approval.
    Administrative address only - do not send returns here without prior confirmation:
    ELECOK CO., LIMITED
    Room 1007, Xiwan Building
    No. 15 Jinhai Road, Bao'an District
    Shenzhen, Guangdong 518102
    China

    International returns may require longer transit times due to shipping distances and customs clearance procedures.

    Liability for Impairment

    You are responsible for any reduction in the value of the product resulting from handling that goes beyond what is necessary to determine the nature, characteristics, and proper functioning of the product.

    Return Shipping Costs

    The buyer is responsible for return shipping costs when exercising the 14-day withdrawal right.

    If the product has quality issues, ELECOK CO., LIMITED will cover the return shipping cost.

    We recommend that customers keep a proof of shipment when returning a product.

    Import duties or import VAT may be charged by customs and are not included in our product prices.

    We will also reimburse the cost of the least expensive standard delivery method we offer when the 14-day withdrawal right is exercised, in accordance with applicable EU/EEA rules.

    Refunds

    Refunds will be issued within 1–2 business days after we receive and inspect the returned item(s), and no later than 14 days from the date we are notified of your withdrawal.

    Refunds will be processed using the same payment method used for the original purchase.

    No additional fees will be deducted from the refund, except for return shipping costs where applicable.

    Exceptions

    Custom-ordered or special-order components are non-returnable.

    Integrated circuits (ICs) and sensitive components that were soldered, installed, or altered cannot be returned.

    Free Replacement or Full Refund Policy

    Product cannot be used during the warranty period due to quality issues

    Product is damaged during transit

    Product is not delivered on time due to reasons on our side

    Process for Free Replacement or Full Refund

    Buyers contact our customer service by email to describe the problem and provide evidence (clear photos, screenshots, or video)

    We will check the problem within 1 working day. For eligible cases, we will process a free replacement or full refund within 1–2 business days

    If a return is required, we will cover the return shipping cost

    Standard Withdrawal Form

    Please do not send packages to the address below without prior confirmation.

    — To: ELECOK CO., LIMITED
    — Email: [email protected]
    — I hereby notify my withdrawal from the contract for the following product(s):
    — Order Number:
    — Product(s):
    — Consumer's Name:
    — Consumer's Address:
    — Date of Receipt:
    — Date of Withdrawal:
    — Signature (only if submitted on paper)

    Contact Information:
    Email: [email protected]
    Phone: +86 755-86211480
    Company: ELECOK CO., LIMITED

    E2K-L13MC1 Proximity Switch NEW

    Gross Weight 0.07